Evaluation of the luminous and thermal comfort in a 'transparent' office space with single and double-glazing under a sunny clear sky

  • Toufik Mezerdi Laboratoire de Conception et de Modélisation des Formes et des Ambiances Architecturales (LACOMOFA), Université de Biskra, B.P. 145 R.P. 07000, Biskra
  • Azeddine Belakehal Laboratoire de Conception et de Modélisation des Formes et des Ambiances Architecturales (LACOMOFA), Université de Biskra, B.P. 145 R.P. 07000, Biskra
  • Amar Bennadji Scott Sutherland School or Architecture and Built Environment, Robert Gordon University, Garthdee Road, Aberdeen, AB10 7QB, Scotland

Abstract

The main objective of this study is to evaluate the light and thermal comfort in a 'transparent' office. This last term designates a working space whose outer wall is entirely glazed by a simple transparent glazing in a first case, and a transparent double glazing in a second case, in the context of arid environments with a hot and dry climate and therefore under the sky Bright sunny. Various solar protections are used for the case of simple glazing and the best performing among them is maintained for office simulations with double-glazing. The study was carried out using an experimental approach. Thus, computer simulations using ECOTECT and RADIANCE softwares were carried out for transparent desk models in order to evaluate: i) illuminance on the worktop ii) luminance in the field Visual, (iii) indoor air temperatures, (iv) and annual energy consumption. It was carried out for south-facing offices at a location with a latitude of 34.48° North and a longitude of 5.73° East. The evaluation of the results obtained is based on recommended reference values ​​for the various simulated indicators. Based on the results obtained from natural light and thermal performance in a single-glazed transparent office, the cases tested were classified according to their degrees of performance in order to choose the optimal orientation for the case of south orientation. In this respect, one notes essentially the performance of the office whose facade is a curtain wall double transparent windows oriented South equipped with a system 'Light shelf'.

Published
2018-05-17
How to Cite
MEZERDI, Toufik; BELAKEHAL, Azeddine; BENNADJI, Amar. Evaluation of the luminous and thermal comfort in a 'transparent' office space with single and double-glazing under a sunny clear sky. Journal of Applied Engineering Science & Technology, [S.l.], v. 3, n. 2, p. 97-103, may 2018. ISSN 2571-9815. Available at: <https://revues.univ-biskra.dz./index.php/jaest/article/view/3862>. Date accessed: 23 nov. 2024.
Section
Section F: Architectural and Building Engineering

Most read articles by the same author(s)